The DUNE experiment will implement a photon detection system composed of X-ARAPUCA (XA) devices. These trap incoming VUV photons by internal reflection in a wavelength shifter light guide to be collected onto silicon photomultiplier arrays, sensitive to visible light. In the baseline design, dichroic filters are used to prevent photons from escaping. The configuration proposed for DUNE’s Vertical Drift (VD) (VD) module has been characterised in liquid argon for the first time using dedicated cryogenic setups developed at CIEMAT and INFN Naples. Additionally, several alternative configurations, based on the design optimisation studies of an R&D campaign, have been evaluated. The results show an efficiency of up to (4.5 ± 0.4)% at 4.5 V overvoltage, representing a significant improvement over previous XA implementations. Most notably, configurations without dichroic filters show an improvement of up to 18%, attributed to transmittance losses in the dichroic filters.
Botogoske, G., Bruni, F., Calvo, E., Calabrese, R., Canci, N., Canto, A., et al. (2026). Measurement of the X-ARAPUCA’s absolute photon detection efficiency for the deep underground neutrino experiment’s vertical drift far detector. EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 86(8) [10.1140/epjc/s10052-026-16190-1].
Measurement of the X-ARAPUCA’s absolute photon detection efficiency for the deep underground neutrino experiment’s vertical drift far detector
Bruni, F.;Galizzi, F.;Gotti, C.;Meazza, L.;Minotti, A.;Terranova, F.;
2026
Abstract
The DUNE experiment will implement a photon detection system composed of X-ARAPUCA (XA) devices. These trap incoming VUV photons by internal reflection in a wavelength shifter light guide to be collected onto silicon photomultiplier arrays, sensitive to visible light. In the baseline design, dichroic filters are used to prevent photons from escaping. The configuration proposed for DUNE’s Vertical Drift (VD) (VD) module has been characterised in liquid argon for the first time using dedicated cryogenic setups developed at CIEMAT and INFN Naples. Additionally, several alternative configurations, based on the design optimisation studies of an R&D campaign, have been evaluated. The results show an efficiency of up to (4.5 ± 0.4)% at 4.5 V overvoltage, representing a significant improvement over previous XA implementations. Most notably, configurations without dichroic filters show an improvement of up to 18%, attributed to transmittance losses in the dichroic filters.| File | Dimensione | Formato | |
|---|---|---|---|
|
Botogoske et al-2026-Eur. Phys. J-VoR.pdf
accesso aperto
Tipologia di allegato:
Publisher’s Version (Version of Record, VoR)
Licenza:
Creative Commons
Dimensione
3.42 MB
Formato
Adobe PDF
|
3.42 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.