Aim: To compare synovial blood flow scoring between different technologies and ultrasound (US) systems in active and inactive rheumatoid arthritis (RA). Material and methods. Fifty-nine RA patients underwent B-mode, power Doppler (PD), colour Doppler (CD), B-Flow and High-Resolution (High-Res) PDI assessments of 6 joints with two US systems at two European centres. Each joint was semi-quantitatively scored for all ultrasound parameters. PD, CD and High-Res PDI synovial signal was also quantitatively scored. Results. Correlations between the total score of SH with system 1 and 2 were very high (≥ 0.90, p<0.0001). Baseline correlations between systems for PD and CD total scores were moderate to very high (0.44-0.96, p<0.05). At baseline, there were no significant differences between ultrasound systems for PD or CD semiquantitative-based total scores in active or inactive patients (p>0,05). B-Flow and High-Res total scores were significantly lower than PD or CD total scores (p<0.05). Conclusion. A high-end and an entry-level US system were interchangeable for scoring SH and showed similar sensitivity and responsiveness in scoring synovial blood flow by PD and CD but not interchangeability. B-Flow and High-Res PDI were responsive, but they showed different sensitivity to detect synovial blood flow compared to conventional Doppler.

Iagnocco, A., Martinez-Estupinan, L., Figus, F., Olivas-Vergara, O., Zabotti, A., Borges, P., et al. (2024). How much different is the semi-quantification of synovitis according to the ultrasound system and the blood flow detection technology?. MEDICAL ULTRASONOGRAPHY, 26(3), 256-263 [10.11152/mu-4391].

How much different is the semi-quantification of synovitis according to the ultrasound system and the blood flow detection technology?

Rozza D.;
2024

Abstract

Aim: To compare synovial blood flow scoring between different technologies and ultrasound (US) systems in active and inactive rheumatoid arthritis (RA). Material and methods. Fifty-nine RA patients underwent B-mode, power Doppler (PD), colour Doppler (CD), B-Flow and High-Resolution (High-Res) PDI assessments of 6 joints with two US systems at two European centres. Each joint was semi-quantitatively scored for all ultrasound parameters. PD, CD and High-Res PDI synovial signal was also quantitatively scored. Results. Correlations between the total score of SH with system 1 and 2 were very high (≥ 0.90, p<0.0001). Baseline correlations between systems for PD and CD total scores were moderate to very high (0.44-0.96, p<0.05). At baseline, there were no significant differences between ultrasound systems for PD or CD semiquantitative-based total scores in active or inactive patients (p>0,05). B-Flow and High-Res total scores were significantly lower than PD or CD total scores (p<0.05). Conclusion. A high-end and an entry-level US system were interchangeable for scoring SH and showed similar sensitivity and responsiveness in scoring synovial blood flow by PD and CD but not interchangeability. B-Flow and High-Res PDI were responsive, but they showed different sensitivity to detect synovial blood flow compared to conventional Doppler.
Articolo in rivista - Articolo scientifico
Doppler; rheumatoid arthritis; scoring; synovitis; ultrasound;
English
11-giu-2024
2024
26
3
256
263
none
Iagnocco, A., Martinez-Estupinan, L., Figus, F., Olivas-Vergara, O., Zabotti, A., Borges, P., et al. (2024). How much different is the semi-quantification of synovitis according to the ultrasound system and the blood flow detection technology?. MEDICAL ULTRASONOGRAPHY, 26(3), 256-263 [10.11152/mu-4391].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/605329
Citazioni
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
Social impact